The C400 series

C400 flow / consumption sensor (insertion type)

 

 

The C400 flow sensor  is based on the thermal mass flow principle. It measures volumetric standard flow over a wide measuring range. The result is pressure and temperature independent.


The sensor installation into the pipe is done through a ½” ball valve. This makes it possible to do the installation under pressure without shutting down the compressed air line.The sensor is available in two measuring ranges and with or without display. The version with display shows the actual volumetric flow and the total consumption. Via the keyboard tube diameters and the consumption counter can be set.


Every sensor includes an analogue output (4…20mA) for flow and an isolated pulse output for the consumption counter.

Special Features

  • Integrated display for m3/h and m3
  • Depth scale for accurate installation
  • Usable from 1/2” to 12” (DN 300)
  • Easy installation under pressure
  • 4...20 mA analogue output for m3/h resp. m3/min
  • Pulse output for m3
  • Inner diameter adjustable via keypad
  • Consumption counter resettable
  • Insertion type sensor for installations under pressure
  • Thermal mass flow, independent of pressure and temperature changes

 

Technical data
 

C400  Measured unit  m3/h, m3/min, l/min, cfm  

Accuracy  +- (3% of measured value + 0.3% full scale)  

Medium  Air, gas, non explosive  

Operating temperature   -30 ... 140 ºC probe tube                                  

 -30 ... 70 ºC casing  

Operating pressure  Up to 50 bar  

Analogue output : 4 ... 20 mA Scaling:   0 ... max range  

Pulse output  1 pulse per m3  

Power supply  12 ... 30 VDC, 100 mA

Volumetric Flow ranges

Inch mm Standard [m3/h] Max [m3/h]
1" 27.3  
0.5...150  0.6....320 
2" 53.1 
2...600 
2.5....1200
3" 84.9  5...1600 7....3400
4" 100.3 9...2700 12....5700
5" 133.7 13...4000 18....8400 
6" 162.3 18...5800 25...12000
8"
200.0 26...8800 33...18000
10"
250.0 40...13700 52...29000
12"
300.0 60...19800  80...40000
The stated flow rates are standard flows at 20 ºC and 1000 mbar  




Applications (*)

 

  • compressed air
  • nitrogen
  • argon
  • helium
  • CO2

(*) state type of gas on order

 

 

Precise installation and removal under pressure

 

Alignment aid

Precise installation with alignment aid

included in set